Broken pool pump

On-site repair of a pool pump

Our friend https://www.jardineriajlcaravaca.es/ call us for a broken pool pump.

We are in a hurry because the house has to be rent very soon.

The first problem we see is the dirtiness that blocks skimmers and pump prefilter

Let’s open and clean the hydraulic part

And now we focus on the electrical part.

Analysis of motor and electrical part:

The capacitor is damaged. To keep on fixing the pump on-site, we need to understand if the pump is worth repairing or if will be necessary to install a new one, so we install a new capacitor, check the old thermal protector and we execute a couple of electrical tests to the motor.

The pump motor passes all the electrical tests, so we execute a noise test on the ball bearings.

Ball bearings noise test:

https://youtu.be/WNwzHj5D9kg

Ball bearings noise is acceptable. The pump can work the whole summer before to make the maintenance.

It’s possible to reinstall the pool pump and leave it at work immediately using the only bottom inlet and leaving the skimmer inlet valve closed.

We tell to the new gardener that it’s important to leave the skimmer inlet valve closed, until the skimmers will be cleaned.

Eventually, we purge the air from the system and leave the pump ready to work:

https://youtu.be/qMgb8zBythI

We also make a work report, programming the periodical maintenance and some adjustments to the system to avoid future problems.

 

 